Handheld Raman for Counterfeit Pill Investigations
Counterfeit pills containing fentanyl and other dangerous substances present a critical public safety challenge. Handheld Raman and optional SERS capability support presumptive identification during law enforcement operations.
The Counterfeit Pill Crisis
Counterfeit pills pressed to resemble legitimate prescription medications — including oxycodone, Adderall, and Xanax — have become a major driver of overdose deaths in the United States. These pills frequently contain fentanyl or fentanyl analogs at varying and unpredictable concentrations. Law enforcement agencies need reliable field identification tools to assess suspected counterfeit pills during operations.
Standard Raman and Counterfeit Pills
The Serstech Arx mkII can support presumptive identification of the primary substance in a counterfeit pill using standard 785 nm Raman spectroscopy. When fentanyl is present at sufficient concentration, it may be detectable in the bulk sample. However, the ability to detect fentanyl in a pill depends on its concentration and distribution within the sample.
SERS for Trace-Level Detection
When fentanyl or other substances are present at very low concentrations — as may be the case in some counterfeit pills — standard Raman may not detect them reliably. The optional SERS (Surface-Enhanced Raman Scattering) accessory for the Arx mkII extends detection capabilities to trace-level concentrations. Agencies with specific trace-detection requirements should discuss SERS capability with Charlie Six.
Operational Considerations
Counterfeit pill investigations involve unique operational considerations. Pills may contain multiple active substances at varying concentrations. The Arx mkII's multicomponent identification capability can help characterize complex samples. Through-container scanning may be possible for pills in transparent packaging, reducing direct handling.
Distinguishing Standard Raman from SERS
It is important to understand the distinction between standard Raman and SERS capabilities. Standard Raman identifies bulk substances — the primary component of a sample. SERS is specifically designed for trace-level detection and requires the SERS accessory and reagents. Not all Arx mkII configurations include SERS. Contact Charlie Six to discuss which configuration meets your agency's requirements.
Presumptive Identification — Important Note
Handheld Raman and SERS provide presumptive identification results. Field results should be followed by laboratory confirmation. The ability to detect a specific substance depends on its concentration and presence in the current spectral library. Consult your agency's legal and forensic advisors regarding the use of field identification results.
Request a Quote or Demonstration
Fill out the form and a Charlie Six representative will respond within one business day.